Browsed by
Tag: refractory

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate  b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play  c. Threezone monitoring of: i)Primary chamber               ii) Secondary chamber               iii) Hot hearth d. Digital display e. Burner on-off indication lights  f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system  c. Maximum noise at 1m x g0 decibels  d. Exterior temperature 70 deg.C Max

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate  b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play  c. Threezone monitoring of: i)Primary chamber               ii) Secondary chamber               iii) Hot hearth d. Digital display e. Burner on-off indication lights  f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system  c. Maximum noise at 1m x g0 decibels  d. Exterior temperature 70 deg.C Max

Medical Incineraotors chamber of post combustion

Medical Incineraotors chamber of post combustion

1.A chamber of post combustion of gases A burner of combustion of gases, A device of injection of air allowing a total re-combustion of gases, A device of air inlet of cooling of waste gases, A sheath of evacuation of the gases burnt, Carcass in strong sheet steel with support of connection Composition of the refractory; Refractory concrete: Thickness :>150mm Nature: 65%% of Al203 Insulate in fibrous panels: Thickness: >85mm Nature: Calcium Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation,  electromagnetic sluice gate of regulation and isolating valve. A secondary injection of air to ensure perfect oxygen content. 2.A control box ensuring the complete cycle of combustion. 3.Fan: Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of  the automatic cycle. 4.Controls and regulations: Control box watertight to dust, including: A switch circuit breaker for each engine (ventilators and burners). A timer with adjustable temporization for the regulation of each burner. A regulator with digital watching for the temperature of combustion. A regulator with digital watching for the temperature of post-combustion. Electric box. 5.The de-ashing must be done in the bottom of the combustion chamber or the de-ashing should be automatic or manual batch de-ashing. 6.Process filtering system: scrubber to be mentioned as optional 7.Emission standards compliance: BS 3316 or equivalent standard 8.Capacity to treat plastic: not less than 40% by weight 9.CE manufacturing compliance: BS EN 746-2-1997